Indexed by:
Abstract:
针对空气源热泵全工况运行所面临的结霜、除霜、低温运行、脏堵等关键问题,结合北京地区的实际工程案例,揭示了机组实际运行特性和供热(冷)特性劣化程度,分析了机组在供暖季与供冷季的整体运行性能.提出了高效抑霜、控霜、低温运行及脏堵诊断技术等相应解决对策,以期促进空气源热泵在北京地区实现全工况高效节能运行.