Indexed by:
Abstract:
以A2O-生物接触氧化(BCO)工艺系统反硝化除磷活性污泥为研究对象,应用Central Composite Design(CCD)设计考察了起始COD浓度、硝酸盐氮浓度、反应温度和缺氧反应时间对反硝化除磷反应的3个响应值COD去除率(Ycod)、N去除率(Yn)和P去除率(Yp)的影响。结果表明,起始COD对反硝化除磷反应中COD、N和P的去除都有重要影响,且缺氧反应时间对Yn有较大影响,反应温度对Yp有很大影响;3个响应值的模型方程均显著,R2分别为0.9853、0.9118和0.9972;当COD为316.95 mg·L-1、硝酸盐氮为42.26 mg·L-1、反应温度为27.19℃、缺...
Keyword:
Reprint Author's Address:
Email:
Source :
化工学报
Year: 2015
Issue: 04
Volume: 66
Page: 1467-1475
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 8
Affiliated Colleges: