An abdominal aortic aneurysm (AAA) is an irreversible dilation of the abdominal artery. Once an aneurysm is detected by doctors, clinical intervention is usually recommended. The interventions involve traditional open surgery repair and endovascular aneurysm repair with a stent graft. Both types of prophylactic procedures are expensive and not without any risk to the patient. It is very difficult to balance the risk of aneurysm repair and the chance of rupture. The reason lies in that the changing trend of characteristic physical quantities with the evolution of AAA and the mechanisms that give rise to it are still not completely clear. In this study, computational 3D patient-specific model for investigating AAA development was established based on computed tomography (CT) images. Results showed that as the aneurysm evolved, peak wall stress and time-averaged wall shear stress distribution patterns changed. The expansion of AAA wall resulted in the increment of peak stress. The AAA wall compliance not only showed different magnitudes at different cross-sections of the aneurismal body, but also changed with the development of the aneurysm. Furthermore, minimum wall strength and rupture potential index during the three stages of AAA evolution were also investigated in detail. This study might provide valuable information on how to further explore the mechanical basis and the rupture potential during AAA evolution, and that it may assist clinical diagnostic procedures and avoid the potential risk of unnecessary surgical intervention.

Keyword:

fluid-structure interaction stress strength rupture risk aneurysm development patient-specific study

Author Community:

  • [ 1 ] [Wang, Xiaohong]Beijing Univ Technol, Biomech Res Lab, Coll Mech Engn & Appl Elect Technol, Beijing, Peoples R China
  • [ 2 ] [Li, Xiaoyang]Beijing Univ Technol, Biomech Res Lab, Coll Mech Engn & Appl Elect Technol, Beijing, Peoples R China

Reprint Author's Address:

  • [Wang, Xiaohong]Beijing Univ Technol, Biomech Res Lab, Coll Mech Engn & Appl Elect Technol, 100 Pingleyuan, Beijing, Peoples R China

Show more details

Related Keywords:

Source :

COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING

ISSN: 1025-5842

Year: 2013

Issue: 9

Volume: 16

Page: 1032-1039

1 . 6 0 0

JCR@2022

ESI Discipline: COMPUTER SCIENCE;

JCR Journal Grade:2

CAS Journal Grade:3

Cited Count:

WoS CC Cited Count: 9

SCOPUS Cited Count: 9

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 10

Online/Total:616/10509424
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.