通过Q420双角钢十字组合截面压杆试验,研究长细比为40,50,60的Q420双角钢十字组合截面压杆构件稳定承载力以及一字型填板、十字分离式填板和十字焊接式填板3种不同填板形式对承载力的影响.结果表明:现行规范对小长细比下受截面悬伸板件宽厚比影响的双角钢十字组合截面压杆的承载力计算显得保守,影响r材料性能的发挥;在构件长度较大时,为保证双角钢形成组合截面,设置填板是必要的,并且在3种填板形式中十字焊接式填板构件的承载力最大.