Indexed by:
Abstract:
The molecular weight and molecular weight distribution (MWD) of polycarboxylate superplasticizer (PCE) was measured by gel permeation chromatograph (GPC) which combined three different detectors, namely refractive index detector (RI), laser light scattering detector (LS) and viscosity detector (VIS). By conducting numerous experiments, what the different peak stand for in the chromatogram was verified and the best sample concentration range in the GPC experiment was also determined. Besides, based on the analysis to the RI chromatogram, the theory on using peak area ratio to denote concentration ratio was put forward. What's more, the calculation of macromonomer reaction ratio using the peak area in the RI chromatogram was introduced.
Keyword:
Reprint Author's Address:
Email:
Source :
PROGRESS IN POLYMERS IN CONCRETE
ISSN: 1022-6680
Year: 2013
Volume: 687
Page: 461-465
Language: English
Cited Count:
WoS CC Cited Count: 1
SCOPUS Cited Count: 2
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 7
Affiliated Colleges: