Indexed by:
Abstract:
In order to achieve active health monitoring of seven-wire steel strands, single magnetostrictive transducer with two-layer coil is developed and applied for the excitation and reception of ultrasonic longitudinal guided waves simultaneously. The transducer can be conveniently fixed at any single one position on the helical surface of these structures. The inner and outer layers of its coil are used for excitation and reception respectively with the help of same axisymmetric permanent magnets. Experimental results show that chosen ultrasonic longitudinal guided wave mode, L(0,1) at 140kHz, can be excited and received with high signal-to-noise ratio in steel strands by using the developed magnetostrictive transducer. Furthermore, to identify the performance of the transducer, the detection of an artificial defect is also conducted.
Keyword:
Reprint Author's Address:
Email:
Source :
MECHANICAL ENGINEERING AND GREEN MANUFACTURING, PTS 1 AND 2
Year: 2010
Page: 456-461
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count: 2
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 7
Affiliated Colleges: