• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Song, Shuang (Song, Shuang.) | Tsui, Po-Hsiang (Tsui, Po-Hsiang.) | Wu, Weiwei (Wu, Weiwei.) | Wu, Shuicai (Wu, Shuicai.) (Scholars:吴水才) | Zhou, Zhuhuang (Zhou, Zhuhuang.)

Indexed by:

EI Scopus SCIE PubMed

Abstract:

In this paper, we proposed ultrasound homodyned K (HK) imaging based on the noise-assisted correlation algorithm (NCA) for monitoring microwave ablation of porcine liver ex vivo. The NCA-based HK (αNCA and kNCA) imaging was compared with NCA-based Nakagami (mNCA) imaging and NCA-based cumulative echo decorrelation (CEDNCA) imaging. Backscattered ultrasound radiofrequency signals of porcine liver ex vivo during and after the heating of microwave ablation were collected (n = 15), which were processed for constructing B-mode imaging, NCA-based HK imaging, NCA-based Nakagami imaging, and NCA-based CED imaging. To quantitatively evaluate the final coagulation zone, the polynomial approximation (PAX) technique was applied. The accuracy of detecting coagulation area with αNCA, kNCA, mNCA, and CEDNCA parametric imaging was evaluated by comparing the PAX imaging with the gross pathology. The receiver operating characteristic (ROC) curve was used to further evaluate the performance of the three quantitative ultrasound imaging methods for detecting the coagulation zone. Experimental results showed that the average accuracies of αNCA, kNCA, mNCA, and CEDNCA parametric imaging combined with PAX imaging were 89.6%, 83.25%, 89.23%, and 91.6%, respectively. The average areas under the ROC curve (AUROCs) of αNCA, kNCA, mNCA, and CEDNCA parametric imaging were 0.83, 0.77, 0.83, and 0.86, respectively. The proposed NCA-based HK imaging may be used as a new method for monitoring microwave ablation. © 2020 Elsevier B.V.

Keyword:

Polynomial approximation Ultrasonic imaging Microwaves Stress intensity factors Ablation Coagulation

Author Community:

  • [ 1 ] [Song, Shuang]Department of Biomedical Engineering, College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
  • [ 2 ] [Tsui, Po-Hsiang]Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan
  • [ 3 ] [Tsui, Po-Hsiang]Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
  • [ 4 ] [Tsui, Po-Hsiang]Medical Imaging Research Center, Institute for Radiological Research, Chang Gung University and Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
  • [ 5 ] [Wu, Weiwei]College of Biomedical Engineering, Capital Medical University, Beijing, China
  • [ 6 ] [Wu, Shuicai]Department of Biomedical Engineering, College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
  • [ 7 ] [Zhou, Zhuhuang]Department of Biomedical Engineering, College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China

Reprint Author's Address:

  • 吴水才

    [wu, shuicai]department of biomedical engineering, college of life science and bioengineering, beijing university of technology, beijing, china

Show more details

Related Keywords:

Related Article:

Source :

Ultrasonics

ISSN: 0041-624X

Year: 2021

Volume: 110

4 . 2 0 0

JCR@2022

ESI Discipline: CLINICAL MEDICINE;

ESI HC Threshold:75

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 11

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 11

Online/Total:891/10659903
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.