• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Zhang, Xiaodong (Zhang, Xiaodong.) | Liu, Xiucheng (Liu, Xiucheng.) (Scholars:刘秀成) | Wu, Bin (Wu, Bin.) | He, Cunfu (He, Cunfu.) (Scholars:何存富) | Uchimoto, Tetsuya (Uchimoto, Tetsuya.) | Takagi, Toshiyuki (Takagi, Toshiyuki.)

Indexed by:

EI Scopus SCIE PubMed

Abstract:

The accuracy of electro-acoustic energy transfer efficiency (EAETE) model directly determines the optimization results of an electromagnetic acoustic transducer (EMAT). In this study, the EMAT model of SH0 mode generation based on magnetostriction mechanism is re-examined. In the existing magnetostriction-based EMAT (MEMAT) analytical model, an approximate method of dynamic magnetic field was employed. Thus the effects of the tested ferromagnetic materials on the dynamic magnetic field in the air is ignored and the boundary condition between air and material is not exact. As a result, the calculated dynamic magnetic field inside the tested ferromagnetic materials is incorrect, thus leading to the calculation errors of magnetostriction body force and the final EAETE of MEMAT. The rigorous analytical solutions for calculating the dynamic magnetic field are derived based on Maxwell equations and boundary conditions in this study. The prediction results of improved analytical model were consistent with previously reported experimental results. Compared with existing analytical models, the improved model showed the higher prediction accuracy of several parameters, including dynamic magnetic field, magnetostriction force and the EAETE. © 2020 Elsevier B.V.

Keyword:

Ferromagnetic materials Boundary conditions Acoustic emission testing Electromagnetic field effects Magnetostriction Ferromagnetism Energy transfer Guided electromagnetic wave propagation Maxwell equations Analytical models

Author Community:

  • [ 1 ] [Zhang, Xiaodong]College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Zhang, Xiaodong]Institute of Fluid Science, Tohoku University, Sendai; 980-8577, Japan
  • [ 3 ] [Liu, Xiucheng]College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 4 ] [Wu, Bin]College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 5 ] [He, Cunfu]College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 6 ] [Uchimoto, Tetsuya]Institute of Fluid Science, Tohoku University, Sendai; 980-8577, Japan
  • [ 7 ] [Takagi, Toshiyuki]Institute of Fluid Science, Tohoku University, Sendai; 980-8577, Japan

Reprint Author's Address:

  • 刘秀成

    [liu, xiucheng]college of mechanical engineering and applied electronics technology, beijing university of technology, beijing; 100124, china

Show more details

Related Keywords:

Related Article:

Source :

Ultrasonics

ISSN: 0041-624X

Year: 2020

Volume: 108

4 . 2 0 0

JCR@2022

ESI Discipline: CLINICAL MEDICINE;

ESI HC Threshold:126

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 18

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 6

Online/Total:1709/10725944
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.