Indexed by:
Abstract:
The molten salt single-tank thermal storage heating system is a low-cost clean energy heating mode that realizes heat storage by built-in electric heaters and heat release by built-in coil heat exchangers. The built-in coil heat exchanger area of this system increases with the increase of heating load, which leads to the arrangement of the coil heat exchanger directly affects the heat release performance of the single tank heat storage system. In order to obtain the best arrangement of coil heat exchanger in a single tank, this paper investigates the effect of different coil heat exchanger arrangements with the same heat exchanger area on the heat release performance of the single tank heat storage system by using numerical calculation method. The results show that the heat release performance of the staggered double spiral coil heat exchanger is better than that of the single row coil heat exchanger, and the capacity, discharge temperature and accumulated heat release are the largest for the arrangement with high inner coil and low outer coil (hi=90 mm, ho=174 mm). The results of this paper provide a theoretical basis for the design of heat exchanger with electrically heating molten salt single tank heat storage. © 2022, Solar Energy Periodical Office Co., Ltd. All right reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
Acta Energiae Solaris Sinica
ISSN: 0254-0096
Year: 2022
Issue: 8
Volume: 43
Page: 209-215
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count: 2
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 7
Affiliated Colleges: