• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Xi, Xiaolu (Xi, Xiaolu.) | Liu, Jincheng (Liu, Jincheng.) | Sun, Hao (Sun, Hao.) | Xu, Ke (Xu, Ke.) | Wang, Xue (Wang, Xue.) | Zhang, Liyuan (Zhang, Liyuan.) | Du, Tianming (Du, Tianming.) | Liu, Jian (Liu, Jian.) | Li, Bao (Li, Bao.)

Indexed by:

Scopus SCIE

Abstract:

Background: The conventional FFRct numerical calculation method uses a model with a multi-scale geometry based upon CFD, and rigid walls. Therefore, important interactions between the elastic vessel wall and blood flow are not routinely considered. Changes in the resistance of coronary microcirculation during hyperaemia are likewise not typically incorporated using a fluid-structure interaction (FSI) algorithm. It is likely that both have resulted in FFRct calculation errors.Objective: In this study we incorporated both the influence of vascular elasticity and coronary microcirculatory structure on FFR, to improve the accuracy of FFRct calculation. Thus, in this study, a physics-driven 3D-0D coupled model including fluid-structure interaction was established to calculate accurate FFRct values.Methods: Based upon a novel geometric multi-scale modeling technology, a FSI simulation approach was used. A lumped parameter model (0D) was used as the outlet boundary condition for the 3D FSI coronary artery model to incorporate physiological microcirculation, with bidirectional coupling between the two models.Results: The accuracy, sensitivity, specificity, and both positive and negative predictive values of FFRDC calculated based upon the coupled 3D-0D model were 86.7, 66.7, 84.6, 66.7, and 91.7%, respectively. Compared to the calculated value using the basic CFD model (MSE = 5.9%, accuracy rate = 80%), the FFRCFD calculated based on the coupled 3D-0D model has a smaller MSE of 1.9%.Conclusion: The physics-driven coupled 3D-0D model that incorporates fluid-structure interactions not only consider the influence of the elastic vessel wall on blood flow, but also provides reliable microvascular resistance boundary conditions for the 3D FSI model. This allows for a calculation that is based upon conditions that are closer to the physiological environment, and thus improves the accuracy of FFRct calculation. It is likely that more accurate information will provide an enhanced recommendation regarding percutaneous coronary intervention (PCI) in the clinic.

Keyword:

0D hemodynamic effects fluid-structure interaction coronary artery 3D geometric multi-scale model fractional flow reserve

Author Community:

  • [ 1 ] [Xi, Xiaolu]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 2 ] [Liu, Jincheng]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 3 ] [Sun, Hao]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 4 ] [Xu, Ke]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 5 ] [Wang, Xue]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 6 ] [Zhang, Liyuan]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 7 ] [Du, Tianming]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 8 ] [Li, Bao]Beijing Univ Technol, Fac Environm & Life, Dept Biomed Engn, Beijing, Peoples R China
  • [ 9 ] [Liu, Jian]Peking Univ Peoples Hosp, Cardiovasc Dept, Beijing, Peoples R China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

FRONTIERS IN PHYSIOLOGY

Year: 2022

Volume: 13

4 . 0

JCR@2022

4 . 0 0 0

JCR@2022

ESI Discipline: BIOLOGY & BIOCHEMISTRY;

ESI HC Threshold:43

JCR Journal Grade:2

CAS Journal Grade:2

Cited Count:

WoS CC Cited Count: 5

SCOPUS Cited Count: 5

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 5

Affiliated Colleges:

Online/Total:814/10667265
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.