• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Bian, Jinliang (Bian, Jinliang.) | Cao, Wanlin (Cao, Wanlin.) (Scholars:曹万林) | Xiong, Cunqiang (Xiong, Cunqiang.) | Lü, Xiaoming (Lü, Xiaoming.) | Ye, Taoping (Ye, Taoping.)

Indexed by:

EI PKU CSCD

Abstract:

To improve fire resistance and thermal insulation performance of composite wall, composite wall of cold-formed steel and tailing microcrystalline foam glass slab (CFS-TS composite wall) was proposed, which was composed of cold-formed steel and tailing microcrystalline foam glass slab (TMFGS). CFS-TS composite wall can fill fly ash blocks between cold-formed steel keels to improve its thermal insulation and mechanical performance. To study the compression performance of CFS-TS composite wall, compressive tests of 4 composite walls were carried out to investigate the influences of the thickness of cold-formed steel, the strength of TMFGS, and the addition of fly ash block on the failure characteristics, bearing capacity, and deformation capacity of specimens. Finite element numerical simulation was conducted to clarify the influence of different parameters on the bearing capacity and failure mode of the composite walls. Simulation results had good agreement with the experimental results. The research shows that CFS-TS composite wall was under axial compression at the early stage of loading and under eccentric compression at the later stage of loading. When the specimen reached the ultimate load, buckling failure occured in the cold-formed steel. The thickness of the cold-formed steel has a great influence on the bearing capacity of the specimen. Increasing the thickness of the cold-formed steel can improve the stability of the specimen. Increasing the strength of the TMFGS can slow down the damage and improve the bearing capacity of the composite wall. When specimen was added with fly ash block, cold-formed steel, TMFGS, and fly ash block had good working performance with each other, and the compressive performance of the specimen was significantly improved. The section form of filling fly ash block is suggested to be used in the engineering application of CFS-TS composite wall. © 2019, Editorial Board of Journal of Harbin Institute of Technology. All right reserved.

Keyword:

Bearing capacity Thermal insulation Fly ash Bearings (machine parts) Studs (structural members) Microcrystals Glass Fire resistance Foams Cold working

Author Community:

  • [ 1 ] [Bian, Jinliang]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Cao, Wanlin]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 3 ] [Xiong, Cunqiang]Beijing North Glass Sinest Technology Co. Ltd., Beijing; 100125, China
  • [ 4 ] [Lü, Xiaoming]Beijing North Glass Sinest Technology Co. Ltd., Beijing; 100125, China
  • [ 5 ] [Ye, Taoping]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China

Reprint Author's Address:

  • 曹万林

    [cao, wanlin]college of architecture and civil engineering, beijing university of technology, beijing; 100124, china

Show more details

Related Keywords:

Related Article:

Source :

Journal of Harbin Institute of Technology

ISSN: 0367-6234

Year: 2019

Issue: 12

Volume: 51

Page: 86-93

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 3

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 8

Online/Total:1273/10532461
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.