• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Jiazheng, W. (Jiazheng, W..) | Guoyuan, M. (Guoyuan, M..) | Guoxin, Y. (Guoxin, Y..) | Wanpeng, Z. (Wanpeng, Z..) | Qianqian, G. (Qianqian, G..) | Shuxue, X. (Shuxue, X..)

Indexed by:

Scopus

Abstract:

The experimental system of household air-source heat pump water heater with flash tank was set up, and its operation performance at different temperatures was studied in the environmental control room, and compared with the single-stage compression system. The results show that the heating capacity and heating COP of the household air-source heat pump water heater with flash tank are greater than that of the single-stage compression system, and the heating capacity increases 21. 3% when the ambient temperature is -15 ℃. The heating time of air-source heat pump water heater with flash tank system is shortened by 20. 1% compared with that of single-stage system under the same water volume and initial and ending temperatures. The discharge temperature of the compressor is reduced by 11. 3 ℃, which ensures the operation safety of the unit. The calculation of APF shows that the system of flash tank replenishment is better in the area with lower ambient temperature. © 2022 Authors. All rights reserved.

Keyword:

flash tank heat pump water heater vapor-injection heating performance

Author Community:

  • [ 1 ] [Jiazheng W.]Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
  • [ 2 ] [Guoyuan M.]Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
  • [ 3 ] [Guoxin Y.]Qingdao Haier Intelligent Technology R&D Co., Ltd., Qingdao, 266101, China
  • [ 4 ] [Wanpeng Z.]Qingdao Haier Intelligent Technology R&D Co., Ltd., Qingdao, 266101, China
  • [ 5 ] [Qianqian G.]Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
  • [ 6 ] [Shuxue X.]Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Source :

Journal of Refrigeration

ISSN: 0253-4339

Year: 2022

Issue: 6

Volume: 43

Page: 100-106

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 3

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Affiliated Colleges:

Online/Total:388/10457788
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185