Abstract:

In latent heat storage units, phase change materials are often combined with metal foams to enhance heat transfer due to their low thermal conductivity. However, the current metal foam structure cannot solve the problems of long melting time and uneven melting caused by natural convection. To obtain superior heat storage structures, this paper uses a multichannel flat tube as the heat exchange element and designs units with a var-iable volume ratio of gradient copper foam. This tube is divided into parts A and B and has a decreasing porosity along the vertical direction from top to bottom. Results of orthogonal tests show that low porosity, a large volume ratio of part A, and a large gradient can improve the performance. An average porosity of 0.84, gradient of 9%, and part A volume ratio of 80% are selected as the optimal structural parameters. Compared with a homogeneous porosity structure having a porosity of 0.96 under original working conditions, the optimal structure has 48.64% higher heat storage capacity and 54.13% shorter melting time. Meanwhile, compared with a homogeneous porosity structure having the same porosity of 0.84, the optimal structure has an 11.37% higher heat storage capacity and 4.09% shorter melting time.

Keyword:

Latent heat storage unit Multichannel flat tube Gradient copper foam Gravimetric specific power Orthogonal test

Author Community:

  • [ 1 ] [Diao, Yanhua]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 2 ] [Wang, Zhen]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 3 ] [Zhao, Yaohua]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 4 ] [Wang, Zeyu]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 5 ] [Chen, Chuanqi]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 6 ] [Zhang, Dengke]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China
  • [ 7 ] [Zhao, Yaohua]Zibo Boi Energy Sci & Technol Co Ltd, Zibo 255000, Shandong, Peoples R China

Reprint Author's Address:

  • [Diao, Yanhua]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient T, Beijing 100124, Peoples R China

Show more details

Related Keywords:

Source :

APPLIED THERMAL ENGINEERING

ISSN: 1359-4311

Year: 2023

Volume: 229

6 . 4 0 0

JCR@2022

ESI Discipline: ENGINEERING;

ESI HC Threshold:19

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Affiliated Colleges:

Online/Total:2112/10900201
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.