• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Tang, J. (Tang, J..) | Wang, J. (Wang, J..) | Shi, Z. (Shi, Z..)

Indexed by:

EI Scopus

Abstract:

The installation errors have great influence on the measurement results of gear measurement center (GMC). Focused on the problem of the ZC1 worm helix deviations evaluation method, based on the measurement principle of ZC1 worm helix in GMC, the influence mechanism of installation errors on worm measurement is analyzed. The installation error correction model is formulated, and the evaluation method of ZC1 worm helix deviations based on installation error correction is established according to the definition of helix deviations. The measurement of ZC1 worm helix deviations is implemented on the GMC, and the helix deviations evaluation results are obtained under the installation conditions. The maximum difference between the measurement results before and after the installation error correction is reduced from 76. 2 μm to 4. 2 μm. The ZC1 worm helix deviation evaluation method proposed can effectively eliminate the influence of installation errors on the helix deviations measurement results during the measurement of GMC. © 2023 Science Press. All rights reserved.

Keyword:

gear measurement center helix deviation installation errors ZC1 worm evaluation

Author Community:

  • [ 1 ] [Tang J.]Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
  • [ 2 ] [Tang J.]Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing, 100124, China
  • [ 3 ] [Wang J.]Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
  • [ 4 ] [Wang J.]Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing, 100124, China
  • [ 5 ] [Shi Z.]Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
  • [ 6 ] [Shi Z.]Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing, 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Source :

Chinese Journal of Scientific Instrument

ISSN: 0254-3087

Year: 2023

Issue: 4

Volume: 44

Page: 181-188

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 6

Affiliated Colleges:

Online/Total:750/10582321
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.