• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Wang, Shuai (Wang, Shuai.) | Yang, Yanling (Yang, Yanling.) (Scholars:杨艳玲) | Li, Xing (Li, Xing.) (Scholars:李星) | Xiang, Kun (Xiang, Kun.) | Zhao, Li (Zhao, Li.)

Indexed by:

EI Scopus PKU CSCD

Abstract:

Focused on the potential threat of the membrane fouling to the bio-safety of the drinking water in the second water supply, this study investigated the effect of shock chlorine and chloramine disinfection on the total Bacteria, Escherichia Coli and Heterotrophic (HPC) bacteria as well as the structure of the biofilm in the BAR-simulated secondary water supply system. The results showed that the number of microbes in the biofilm reached maximum on the 80th day and soon it fluctuated smoothly. The Firmicutes, Proteobacteria and Bacteroidetes were predominant bacteria by Metagenomic approaches. The effect of chlorine and chloramine disinfection on the biofilm was related to the concentration of the disinfectant as well as the concentration and time(CT). At the same CT value, higher concentration of Chlorine and chloramine had more effective disinfection. Comparison and analysis found that in low concentrations, compared to chloramine, chlorine is more effective to total Bacteria and Escherichia Coli, while less effective to HPC. However, in high concentrations, chlorine and chloramine own nearly the same inactivated effect. When the concentration of chlorine and chloramine was 3.0 mg/L and the CT value was 300-400 mg·min/L, the inactivation rate of total Bacteria, Escherichia Coli and HPC was as high as 95%. Scanning Electron Microscope(SEM) images of biofilm surface plot analysis illustrated that the structure of biofilm was damaged seriously, and shock chlorine disinfection, compared to chloramine, possessed less impact to the structure and reduction degree of the biofilm and was hence more conducive to the biofilm control. © 2017, Editorial Board of Journal of Harbin Institute of Technology. All right reserved.

Keyword:

Membrane fouling Water supply systems Escherichia coli Disinfection Computerized tomography Chlorine Potable water Water supply Biofilms Scanning electron microscopy

Author Community:

  • [ 1 ] [Wang, Shuai]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Yang, Yanling]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 3 ] [Li, Xing]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 4 ] [Xiang, Kun]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 5 ] [Zhao, Li]China Architecture Design & Research Group, Beijing; 100044, China

Reprint Author's Address:

  • 杨艳玲

    [yang, yanling]college of architecture and civil engineering, beijing university of technology, beijing; 100124, china

Show more details

Related Keywords:

Source :

Journal of Harbin Institute of Technology

ISSN: 0367-6234

Year: 2017

Issue: 8

Volume: 49

Page: 71-77

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 4

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 5

Online/Total:406/10625322
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.