Abstract:

A pilot-scale bio-filter was constructed for the removal of high concentrations of iron (TFe 9.0-12.0 mg·L-1, Fe(II) 6.5-8.0 mg·L-1), manganese (1.9-2.1 mg·L-1), and ammonia nitrogen (1.4-1.7 mg·L-1) simultaneously from low temperature (5-6) groundwater in a plant. The results showed that iron was removed at the beginning of the bio-filter start-up, and manganese and ammonia nitrogen were removed on day 72 and day 75, respectively. The start-up period was influenced by the culture temperature and the raw water quality. For higher filtration rates, the removal of manganese was lower. When the filtration rate was more than 1.0 m·h-1, the maximum removal of manganese was about 3.0 mg·L-1. Manganese was the limiting factor for the increase of filtration rate, and the maximum filtration rate of the single bio-filter was 4.5 m·h-1. When the filtration rate was less than 6.0 m·h-1, the removal of ammonia nitrogen was about 1.5 mg·L-1, which was not affected by the filtration rate. Dissolved oxygen (DO) deficiency led to failure with the removal of more ammonia nitrogen. The required thickness of the bio-filter required for purification increased as the concentration of manganese and ammonia nitrogen increased when DO was sufficient. The removed iron, manganese, and ammonia nitrogen move to the depth of the filter layer, and there will be 'manganese dissolution' when the filtration rate is increased. Iron and ammonia nitrogen in the filter layer can be oxidized and removed simultaneously. Manganese is oxidized and removed after the iron and ammonia nitrogen. The effective oxidation and removal section of manganese, iron, and ammonia nitrogen are obviously graded. © 2017, Science Press. All right reserved.

Keyword:

Water quality Chemicals removal (water treatment) Iron compounds Reactor startup Nitrogen removal Temperature Ammonia Dissolved oxygen Nitrogen Oxidation Passive filters Groundwater

Author Community:

  • [ 1 ] [Li, Dong]Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Cao, Rui-Hua]Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 3 ] [Yang, Hang]State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin; 150090, China
  • [ 4 ] [Wang, Liu-Yu]Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 5 ] [Zhang, Jie]Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing; 100124, China
  • [ 6 ] [Zhang, Jie]State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin; 150090, China
  • [ 7 ] [Zeng, Hui-Ping]Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing; 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Source :

Environmental Science

ISSN: 0250-3301

Year: 2017

Issue: 12

Volume: 38

Page: 5097-5105

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 10

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 6

Online/Total:483/10573112
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.