Indexed by:
Abstract:
The existing constitutive model of confined concrete is not established on the direct test data,which needs to be verified and modified.In order to accurately measure the internal stress of confined concrete,a miniature large range earth pressure box is developed.The internal strain of concrete is measured by the strain gauges embedded in a resin rod.The relevant sensors are embedded in different positions inside the reinforced concrete prismatic specimens,and finally the axial compression test is carried out to obtain the real stress-strain data of the confined concrete.The stress-strain data at different positions in the confined concrete are comprehensively processed to obtain the equivalent stress-strain curve,and then the traditional constitutive model of confined concrete is modified.Through the finite element simulation analysis of the specimen, the accuracy of the modified constrained concrete constitutive model is preliminarily verified. The accuracy of the modified constitutive model and the test technique is further verified by the static loading failure test data and finite element simulation of reinforced concrete columns. © 2024 Editorial Board of Journal of Basic Science and Engineering. All rights reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Basic Science and Engineering
ISSN: 1005-0930
Year: 2024
Issue: 4
Volume: 32
Page: 1170-1185
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 6
Affiliated Colleges: