A nondestructive testing method combining ground -penetrating radar ( GPR) and phased-array ultrasonic testing ( PAUT) was proposed to address the difficulty of detecting defects on the bonding surface of concrete composite slabs. In order to verify the method, and to study the influence of reinforcement on the detection method, a single-layer reinforced composite slab and a double-layer reinforced truss composite slab were designed and fabricated. On the bonding surface, three types of artificial defects were set, delamination,voids, and debris. The detection results show that the method can effectively detect all defect types with accurate defect localization. The relative errors of detecting the size of defects are below 20.0%,and the average errors of detecting two specimens are 8.0% and 6. 6%, respectively, the relative errors of detecting the depth of defects are below 10.0%,and the average errors of detecting two specimens are 4.3% and 4.8%, respectively. This method is an effective and accurate method for detecting defects in the bond surface of concrete composite slabs. © 2024 Chinese Vibration Engineering Society. All rights reserved.