Abstract:

Objective: To design a global sliding mode control algorithm for the purpose of eliminating the chattering effect in conventional sliding mode control algorithm on both the controller and controlled plant from the conventional sliding mode control algorithm and regulating the intra-aorta pump in response to the demand of blood circulation system in human. Methods: A dynamic disturbance compensator was used to estimate the uncertainty of the intra-aorta pump control system. Computer simulations and in vitro experiments were also conducted to verify the dynamic characteristics and robustness of the controller. Results: As the dynamic disturbance compensator was used to estimate the uncertainty of system, the chattering effect in sliding mode control algorithm was eliminated. When the reference flow rate was set at 5 L/min, the response time was 80 ms without any overshot and static error. When the load torque of the controller was increased to 0.4 N · m, the response time was 25 ms. When the pulsatile signal was input as the reference flow rate, the dynamic response time was 80 ms with the maximum error of flow rate being 0.03 L/min. In the in vitro experiments, as the feedback frequency of flow rate signal and pump speed signal were lower than that in the ideal condition, the controller performance was deteriorative compared with computer simulation. The experimental results demonstrated that when the reference flow rate was set at 5 L/min, the response time was 0.26 s with the error of flow rate being 0.1 L/min. Conclusions: The controller provided in this paper can accurately regulate the intra-aorta pump according to the reference flow rate. Furthermore, it has a strong robustness for the uncertainty and disturbance of the control system. Due to the use of dynamic disturbance compensator, the chattering effect of the algorithm has been eliminated.

Keyword:

Robustness (control systems) Blood vessels Man machine systems Uncertainty analysis Sliding mode control Response time (computer systems) Flow rate Errors Hemodynamics Pumps Computer simulation Controllers

Author Community:

  • [ 1 ] [Gao, Bin]School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China
  • [ 2 ] [Gu, Kai-Yun]School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China
  • [ 3 ] [Chang, Yu]School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China
  • [ 4 ] [Liu, You-Jun]School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

Journal of Medical Biomechanics

ISSN: 1004-7220

Year: 2011

Issue: 3

Volume: 26

Page: 279-285

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 12

Online/Total:382/10633458
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.