Abstract:
In order to evaluate the structure safety of cut-and-cover section of Xiamen sub-sea tunnel caused by lack of ground load-bearing capacity, the cut-and-cover tunnel is modeled as a structure loaded by earth and water pressures. The deflections, inner forces and safet of the cut-and-cover tunnel structure are analyzed by a structure analytical software named as ANSYS, and the structure safety factors are calculated. In conclusions, the cut-and-cover tunnel structure is safe before backfilling, but the structure safety is not enough because of the loads of backfilling self-weight. It is suggested that the ground of the cut-and cover tunnel should be treated by reinforced measures.