The cable and the tension bar which belong to the basic frame member of the prestressed long-span steel structure system are high strength steel members which had been subject to cold-work hardening and hot rolling and modified treatment separately. After modifying, the members' strength increased significantly and their ductile nature reduced greatly. Large deformation collapse buckling limiting state of the prestressed long-span steel structure system is the controlling factor of the structure security. So it is very important to analyze the ductile nature of the cable and tension bar for the design of the prestressed long-span steel structure system. This paper takes the suspend-dome of the badminton gymnasium for 2008 Olympic Games for example, attempting to analyze and study the stress and the distort ability of the cable and the tension bar under severe earthquake and overall buckling. The study indicates the mechanical behavior of suspend-dome structure, i.e. large deform in system, small strain in cable and bar. It proves that the cable and bar with low ductility capability is safe to be applied on suspend-dome structure system.