Qionghai is located in the low latitude region where the solar altitude angle is high. It is a typical climate with high temperature, high humidity, intense solar radiation, and small daily temperature variation. Under such climate conditions, designing optimal wall insulation structures is critical for achieving building energy saving. This paper takes a hotel building as a case, to simulate energy consumption of the building with different wall insulation structures in Qionghai by EnergyPlus software. The results show that building envelope insulations have obvious insulation effect, and the energy saving effect of external insulation and sandwich insulation is better than internal insulation. Internal insulation decreased the cold load index of 10.34%, while external insulation and sandwich insulation, respectively, reduce the cold load index of 12.21 and 12.34%. The energy saving effect of the three wall insulation structures would decrease with the increase of autoclaved lime-sand brick layer thickness. © 2020, Springer Nature Singapore Pte Ltd.

Keyword:

Structural optimization Lime brick Energy utilization Walls (structural partitions) Energy conservation Insulation Solar buildings Air conditioning Lime

Author Community:

  • [ 1 ] [Yu, Chenrong]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 2 ] [Xie, Jingchao]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 3 ] [Xue, Peng]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 4 ] [Liu, Jiaping]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing; 100124, China
  • [ 5 ] [Ji, Ying]Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing; 100124, China

Reprint Author's Address:

  • 谢静超

    [xie, jingchao]key laboratory of green built environment and energy efficient technology, beijing university of technology, beijing; 100124, china

Show more details

Related Keywords:

Related Article:

Source :

ISSN: 1863-5520

Year: 2020

Page: 1285-1293

Language: English

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 2

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 14

Online/Total:483/10573112
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.