Hao, Dongmei (Hao, Dongmei.) (Scholars:郝冬梅) | An, Yang (An, Yang.) | Qiao, Xiangyun (Qiao, Xiangyun.) | Qiu, Qian (Qiu, Qian.) | Zhou, Xiya (Zhou, Xiya.) | Peng, Jin (Peng, Jin.)

Indexed by:

EI Scopus SCIE PubMed

Abstract:

Uterine contraction (UC) is an important clinical indictor for monitoring uterine activity. The purpose of this study is to develop a portable electrohysterogram (EHG) recording system (called PregCare) for monitoring UCs with EHG signals. The PregCare consisted of sensors, a signal acquisition device, and a computer with application software. Eight-channel EHG signals, the tocodynamometry (TOCO) signal, and maternal perception were recorded simultaneously by the signal acquisition device controlled by the computer via Bluetooth. PregCare was firstly evaluated by a signal simulator. Its relative error (RE) and coefficient of variation (CV) were calculated, and its agreement with the commercial instrument PowerLab was assessed by Bland-Altman plots. After that, PregCare was applied to 20 pregnant women in a hospital to record their EHG signals. These EHG signals were preprocessed and segmented into UCs and non-UCs. Then, the EHG features corresponding to UCs and non-UCs were extracted, respectively, including power spectral density (PSD), root mean square (RMS), peak frequency (PF), median frequency (MDF), and sample entropy (SamEn). One-way ANOVA was employed to assess the difference between UCs and non-UCs. The results show that RE and CV were less than 8% and 0.03%, respectively, which indicated the high accuracy and repeatability of PregCare. The small differences of mean and standard deviation indicated the high agreement between PregCare and PowerLab. Besides, the PSD of UCs was much larger than non-UCs between 0 and 0.7Hz. RMS of UCs was significantly larger than non-UCs (p<0.05). PF and SamEn of UCs were significantly smaller than non-UCs (p<0.05). In conclusion, the developed EHG recording system was able to record EHG signals reliably. It has the advantages of portability, low power consumption, and wireless transmission, which can be used for long-term monitoring of UCs and prediction of the preterm delivery.

Keyword:

Author Community:

  • [ 1 ] [Hao, Dongmei]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China
  • [ 2 ] [An, Yang]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China
  • [ 3 ] [Qiao, Xiangyun]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China
  • [ 4 ] [Qiu, Qian]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China
  • [ 5 ] [Peng, Jin]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China
  • [ 6 ] [Zhou, Xiya]Peking Union Med Coll Hosp, Dept Obstet, Beijing 100730, Peoples R China

Reprint Author's Address:

  • 郝冬梅

    [Hao, Dongmei]Beijing Univ Technol, Coll Life Sci & Bioengn, Intelligent Physiol Measurement & Clin Translat, Beijing Int Base Sci & Technol Cooperat, Beijing 100024, Peoples R China

Show more details

Related Keywords:

Related Article:

Source :

JOURNAL OF HEALTHCARE ENGINEERING

ISSN: 2040-2295

Year: 2019

Volume: 2019

ESI Discipline: Multidisciplinary;

ESI HC Threshold:255

Cited Count:

WoS CC Cited Count: 14

SCOPUS Cited Count: 15

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Online/Total:607/10714226
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.