In this paper the mathematical model of all-glass vacuum tube collector unit used in passive solar heating system have been established and verified through multiple experiments (different connections, different flow, different weather conditions). Experiments showed that the model had accurate described the heat transfer processes of all-glass vacuum collector. Compared to the empirical formula, the model is simpler and has a higher precision.

Keyword:

Air conditioning Solar energy Heating equipment Solar heating Mathematical models Electron tubes Heat storage Glass

Author Community:

  • [ 1 ] [Li, Zhiyong]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, China
  • [ 2 ] [Chen, Chao]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, China
  • [ 3 ] [Luo, Hailiang]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, China
  • [ 4 ] [Zhang, Ye]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, China
  • [ 5 ] [Xue, Yaning]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

Year: 2009

Volume: 3

Page: 1808-1815

Language: English

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 2

Online/Total:273/10515583
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.