In this paper, we develop an Adaptive Multigrid method (AMGM) to model photon transport through biological tissues in bioluminescence tomography. In our method, the smoothing operation on fine levels and residual correction on coarse levels in V-Cycle offer fast convergence rate for this forward problem. Using a heterogeneous phantom, the methodology is validated by Monte Carlo simulations, and the computation speed is much higher than conventional smoothing iteration methods on a single grid. In actual biomedical imaging applications, especially when there are many sources in small animal body, AMGM is potential to accurately simulate the forward problem at very low computation cost. © 2008 IEEE.

Keyword:

Iterative methods Tissue engineering Phosphorescence Bioluminescence Histology Photons Tomography Medical imaging Tissue Monte Carlo methods

Author Community:

  • [ 1 ] [Liu, Kai]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China
  • [ 2 ] [Tian, Jie]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China
  • [ 3 ] [Wang, Pu]Department of Electronic Information and Control Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 4 ] [Liu, Dan]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China
  • [ 5 ] [Lv, Yujie]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China
  • [ 6 ] [Xu, Min]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China
  • [ 7 ] [Qin, Chenghu]Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190, China

Reprint Author's Address:

Show more details

Related Keywords:

Related Article:

Source :

Year: 2008

Page: 462-465

Language: English

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 2

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 9

Online/Total:892/10670881
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.