Author:

Xue, Peng (Xue, Peng.) (Scholars:薛鹏) | Li, Qian (Li, Qian.) | Xie, Jingchao (Xie, Jingchao.) (Scholars:谢静超) | Zhao, Mengjing (Zhao, Mengjing.) | Liu, Jiaping (Liu, Jiaping.) (Scholars:刘加平)

Indexed by:

EI Scopus SCIE

Abstract:

Daylight is a valuable resource with characters of both photometry and radiometry, and window-to-wall ratio (WWR) is a crucial building envelope element that decides the indoor luminous and thermal environments. Due to the traditional utilize of external shadings and lack of appropriate design standard for buildings in China low latitude region, this study proposes a workflow for optimizing WWR with sunshades by considering both day lighting performance and energy consumption. The reference WWR is firstly decided based on the requirements of daylighting standards by using Radiance for standard room without external shading, and the reference annual cooling load of the whole building is then calculated by EnergyPlus. A large number of cases with different WWRs and external shadings are calculated and energy-saving and daylighting performances are finally verified with reference case. The optimal WWR value range with different sunshades configurations in different orientations is that meets daylighting requirement while below reference annual cooling load. The results indicate that comprehensive sunshades have the best energy performance with the benefits of both horizontal and vertical ones. With a 1.8 m comprehensive sunshade, the lower threshold of WWR raises to 0.40 for meeting daylighting requirement, and the accepted upper threshold of WWR range for west, north, east and south-facing units could reach to 0.56, 0.6, 0.6 and 0.78 respectively. For designing a building with facade the same in all orientations, the largest WWR could be set as 0.7 for west-east buildings and 0.55 for south-north buildings with 1.8 m comprehensive sunshades. The scenario has been verified and this WWR optimization process could be applied to different buildings in other climate regions.

Keyword:

Optimization process Energy-saving Sunshades Daylighting Window-to-wall ratio (WWR)

Author Community:

  • [ 1 ] [Xue, Peng]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing, Peoples R China
  • [ 2 ] [Li, Qian]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing, Peoples R China
  • [ 3 ] [Xie, Jingchao]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing, Peoples R China
  • [ 4 ] [Zhao, Mengjing]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing, Peoples R China
  • [ 5 ] [Liu, Jiaping]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing, Peoples R China

Reprint Author's Address:

  • 谢静超

    [Xie, Jingchao]Room 3506,Environm & Chem Bldg,100 Pingleyuan, Beijing 100124, Peoples R China

Show more details

Related Keywords:

Source :

APPLIED ENERGY

ISSN: 0306-2619

Year: 2019

Volume: 233

Page: 62-70

1 1 . 2 0 0

JCR@2022

ESI Discipline: ENGINEERING;

ESI HC Threshold:136

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count: 103

SCOPUS Cited Count: 114

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Online/Total:1455/10545569
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.