Indexed by:
Abstract:
Many studies have found that the photovoltaic (PV) cell temperature plays an important impact on the solar-to-electricity conversion efficiency. Different cooling liquids like air and water have been introduced to pass across the PVs to reduce the cell temperature, and thus increase the electrical efficiency. In this paper, the refrigerant R134a is used as the cooling liquid and the PV/thermal (PV/T) panel is coupled with a heat pump system acting as the evaporator, which is expected to achieve a better cooling effect and energy performance due to its low boiling temperature. Two different kinds of PV/T panels, glass vacuum tube (GVT) type and flat plate (FP) type, are proposed for the study on the energy performance comparison. The results show that the GVT PV/T panel has an average thermal efficiency of 0.775 and an average electrical efficiency of 0.089 (based on the reference efficiency of 0.12), which is 73.4% and 1.1% higher than that of the FP PV/T panel respectively, with the solar radiation varying from 200 W/m 2 to 1000 W/m 2. The GVT PV/T heat pump system has an average COP of 5.6, 9.8% higher the FP PV/T heat pump system. The GVT PV/T heat pump system has a better energy performance than the FP PV/T heat pump system. © (2012) Trans Tech Publications, Switzerland.
Keyword:
Reprint Author's Address:
Email:
Source :
Advanced Materials Research
ISSN: 1022-6680
Year: 2012
Volume: 446-449
Page: 2888-2894
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 6
Affiliated Colleges: