Indexed by:
Abstract:
This article studies on seismic performance of a ceramic plate curtain wall by shaking table of a steel frame hanging a full scale ceramic plate curtain wall model. In the test, El-Centro seismic waves, artificial wave and 0. 5-50Hz white noise wave were inputted. Results show that the maximum story drift angle is 1/237, it means that the seismic performance of ceramic plate curtain wall system is good,it satisfies the seismic design requirements. In the test, the white noise wave was inputted just after the El-Centro seismic waves and artificial wave which have the same acceleration to detect the changes in the natural frequency of structure. Finally, we fitted out the frequency curve, and it shows that when the earthquake acceleration reaches 300 Gal, the natural frequency of the structure is no longer changeable.
Keyword:
Reprint Author's Address:
Email:
Source :
World Information on Earthquake Engineering
ISSN: 1007-6069
Year: 2012
Issue: 3
Volume: 28
Page: 11-14
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0
Affiliated Colleges: