Author:

Li, X. (Li, X..) | Xu, H. (Xu, H..) | Yang, Y. (Yang, Y..) | Zhao, W. (Zhao, W..) | He, W. (He, W..) | Jia, R. (Jia, R..) | Song, W. (Song, W..) | Liu, Y. (Liu, Y..)

Indexed by:

Scopus PKU CSCD

Abstract:

To exam the effect of coagulation conditions on organic removal efficiency and membrane fouling of the coagulation-ultrafitration process, Yellow Biver reservoir water was studied by using the static ultrafiltration device. Effect of flocculation time on organic removal, flocs characteristics and ultrafiltration characteristics during the ultrafiltration process was investigated in this study and membrane fouling factors were also analyzed. Results indicate that the dissolved organic matter (DOC, UV254) removal mainly attributes to the condensing process, the following flocculation process has no influence. Coagulation time had significant influence on flocs characteristics and membrane fouling, and both shorter and longer time had negative influence. The flocculation time of 10 mins was in the range of optimum, at which the fractal dimension, the normalized flux, the total membrane fouling resistance and the cake fouling resistance up to their minimum. However the normalized flux decline was the biggest and the pore blocking resistance lay in the stable state. 20 mg/L dosage of PAC and 10min of flocculation time is the optimal optimum coagulation conditions in coagulation-ultrafiltration process, while achieving a good flocs property and ultrafiltration characteristics. Insufficient and excessive dosage of PAC would have a great influence on coagulation, flocs and cake layer characteristics. © 2016, Beijing University of Technology. All right reserved.

Keyword:

Coagulation time; Flocs characteristics; Membrane fouling; Organic matter; Ultra-filtration

Author Community:

  • [ 1 ] [Li, X.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 2 ] [Xu, H.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 3 ] [Yang, Y.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 4 ] [Zhao, W.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 5 ] [He, W.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 6 ] [Jia, R.]Jinan Water and Wastewater Monitoring Center, Jinan, 250021, China
  • [ 7 ] [Song, W.]Jinan Water and Wastewater Monitoring Center, Jinan, 250021, China
  • [ 8 ] [Liu, Y.]College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 9 ] [Liu, Y.]China Architecture Design Group, Beijing, 100044, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Related Article:

Source :

Journal of Beijing University of Technology

ISSN: 0254-0037

Year: 2016

Issue: 6

Volume: 42

Page: 946-952

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 1

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 6

Online/Total:938/10609403
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185