Indexed by:
Abstract:
The heat transfer coefficient calculation of the composite EPS template recycled concrete shear-wall was studied in this paper. The relationship between heat transfer coefficients of various materials and temperature, humidity were calculated based on the heat conduction mechanism of the reinforced concrete and EPS template composite. A correction calculation method of heat transfer coefficient was put forward according with the actual working environment. By the comparative analysis of the experimental value, literature reference value and the correction calculation value of the four test specimens, the correction calculation value could more accurately reflect the real value coefficient of heat transfer, and provided a theoretical basis on building energy efficiency design. Taking the composite EPS template recycled concrete shear-wall that applicable to Beijing as an example, the heat transfer coefficient was calculated, analyzed, and compared with the experimental value, which suggested that the correction calculation method for energy saving design was more reasonable. © 2016, The Editorial Board of Journal of Basic Science and Engineering. All right reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Basic Science and Engineering
ISSN: 1005-0930
Year: 2016
Issue: 1
Volume: 24
Page: 81-89
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 4