• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Yang, L. (Yang, L..) (Scholars:杨璐) | Zhang, W. (Zhang, W..) | Zhang, L. (Zhang, L..) | Zhang, S. (Zhang, S..) | Yang, Y. (Yang, Y..) | Wang, Q. (Wang, Q..) (Scholars:王群) | Shao, J. (Shao, J..) | Chen, G. (Chen, G..) (Scholars:陈戈) | Wang, Y. (Wang, Y..)

Indexed by:

Scopus

Abstract:

Purpose: Gestational hypertension (GH) is a serious health hazard for pregnant women and fetuses. The incidence of GH involves many epidemiological, biochemical, and hemodynamic factors. Methods: The current study investigated the GH risk under the influence of epidemiological, biochemical, and hemodynamic factors, and designed corresponding GH risk evaluation methods and apparatus. Results: The evaluation method has 74.15% sensitivity and 81.84% specificity. The ROC area under the curve is 0.841. The apparatus automatically imports epidemiological, biochemical, and hemodynamic factors, and then expresses the GH risk as numbers, bar codes, and colors through logic array analysis. Conclusion: The GH risk value can effectively give the risk level of GH. The GH risk barcode can improve the degree of automation of information storage, transmission, and identification in GH monitoring. The GH risk color can also improve the GH macro description.

Keyword:

Logic switch array; Logistic regression; Risk bar code; Risk factors; Risk value

Author Community:

  • [ 1 ] [Yang, L.]Bioelectronics and Instruments Lab., College of Life Science and Bioengineering, Beijing University of Technology, Pingleyuan 100, Chaoyang District, Beijing 100124, China
  • [ 2 ] [Zhang, W.]Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing, China
  • [ 3 ] [Zhang, L.]Beijing YES Medical Device Co., Ltd., Beijing, China
  • [ 4 ] [Zhang, S.]Bioelectronics and Instruments Lab., College of Life Science and Bioengineering, Beijing University of Technology, Pingleyuan 100, Chaoyang District, Beijing 100124, China
  • [ 5 ] [Yang, Y.]Bioelectronics and Instruments Lab., College of Life Science and Bioengineering, Beijing University of Technology, Pingleyuan 100, Chaoyang District, Beijing 100124, China
  • [ 6 ] [Wang, Q.]Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing, China
  • [ 7 ] [Shao, J.]Beijing YES Medical Device Co., Ltd., Beijing, China
  • [ 8 ] [Chen, G.]Beijing YES Medical Device Co., Ltd., Beijing, China
  • [ 9 ] [Wang, Y.]Beijing YES Medical Device Co., Ltd., Beijing, China

Reprint Author's Address:

  • 杨璐

    [Yang, L.]Bioelectronics and Instruments Lab., College of Life Science and Bioengineering, Beijing University of Technology, Pingleyuan 100, Chaoyang District, Beijing 100124, China

Show more details

Related Keywords:

Related Article:

Source :

Clinical and Experimental Obstetrics and Gynecology

ISSN: 0390-6663

Year: 2013

Issue: 1

Volume: 40

Page: 61-65

0 . 2 0 0

JCR@2022

ESI Discipline: CLINICAL MEDICINE;

JCR Journal Grade:4

CAS Journal Grade:4

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 5

Online/Total:260/10586013
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.