• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Zhao, Q.-G. (Zhao, Q.-G..) | Peng, X.-X. (Peng, X.-X..) | Liu, D. (Liu, D..) | Wang, J.-F. (Wang, J.-F..) (Scholars:王景甫)

Indexed by:

Scopus PKU CSCD

Abstract:

For the purpose of reducing excess heating without sacrifice of human comfortability, a room-temperature monitoring system was developed in this paper. In this system, the measured temperature data were collected by the wireless transmitter/receiver, all of the data were transmitted by internetwork, and the necessary temperature data were displayed through both the software installed in the terminal computer and the database stored in a server. This made a good integration of advantages when the effective signal covering range, location of terminal computer, cost of communications, and practicality of engineering, etc., were taken into account. The practical cost of engineering was acceptable and the cost of communications was avoided, which increased the possibility of applications of such a system. By this system, various room-temperature data within the range of a heating district can be displayed at real time and historically recorded. The heating adjustment can also be clearly reflected in the process of room-temperature evolution curve displayed in the terminal software. It thus concludes that the development of such a system provides a technical basis to local adjustment of room temperature for energy saving. ©, 2015, Beijing University of Technology. All right reserved.

Keyword:

Energy saving in buildings; Room temperature adjustment; Room temperature monitoring system

Author Community:

  • [ 1 ] [Zhao, Q.-G.]Key Lab. of Enhanced Heat Transfer and Energy Conservation, Ministry of Education, Beijing, 100124, China
  • [ 2 ] [Zhao, Q.-G.]Beijing Key Lab. of Heat Transfer and Energy Conversion, Beijing, 100124, China
  • [ 3 ] [Zhao, Q.-G.]College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 4 ] [Peng, X.-X.]Key Lab. of Enhanced Heat Transfer and Energy Conservation, Ministry of Education, Beijing, 100124, China
  • [ 5 ] [Peng, X.-X.]Beijing Key Lab. of Heat Transfer and Energy Conversion, Beijing, 100124, China
  • [ 6 ] [Peng, X.-X.]College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 7 ] [Liu, D.]Key Lab. of Enhanced Heat Transfer and Energy Conservation, Ministry of Education, Beijing, 100124, China
  • [ 8 ] [Liu, D.]Beijing Key Lab. of Heat Transfer and Energy Conversion, Beijing, 100124, China
  • [ 9 ] [Liu, D.]College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, 100124, China
  • [ 10 ] [Wang, J.-F.]Key Lab. of Enhanced Heat Transfer and Energy Conservation, Ministry of Education, Beijing, 100124, China
  • [ 11 ] [Wang, J.-F.]Beijing Key Lab. of Heat Transfer and Energy Conversion, Beijing, 100124, China
  • [ 12 ] [Wang, J.-F.]College of Environmental and Energy Engineering, Beijing University of Technology, Beijing, 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Related Article:

Source :

Journal of Beijing University of Technology

ISSN: 0254-0037

Year: 2015

Issue: 7

Volume: 41

Page: 1079-1084

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 9

Online/Total:1080/10690382
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.