Indexed by:
Abstract:
本文提出热泵驱动热管式辐射供热装置的循环原理,基于1 HP压缩机研制出一套样机,并在焓差室测试了样机在室内温度为18~22℃,室外温度为-15~0℃的工况下的运行特性.结果表明:热管散热器启动迅速、表面温度分布均匀,热管工质的最佳充注比率为0.1,当室内温度为22℃,室外温度为-15~0℃时,制热COP最高可达4.1.
Keyword:
Reprint Author's Address:
Email:
Source :
制冷学报
ISSN: 0253-4339
Year: 2018
Issue: 5
Volume: 39
Page: 67-71
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count: 1
Chinese Cited Count:
30 Days PV: 4
Affiliated Colleges: