提出了连排钢管混凝土柱带钢板耗能键组合剪力墙,它由钢管混凝土连排柱、柱间钢板耗能键、钢板耗能键外包混凝土条带三种单元组合而成.进行了4个不同设计参数试件的低周反复荷载试验研究.分析了各试件的承载力、刚度及其退化过程、滞回特性、延性和破坏特征,探讨了分灾耗能机制.研究表明:连排钢管混凝土柱带钢板耗能键组合剪力墙,承载力较大,后期刚度较稳定;混凝土条带在开裂与闭合过程中消耗地震能量,钢板耗能键通过弯剪变形消耗地震能量,钢管与混凝土条带共同工作协同耗能,具有良好的抗震耗能机制;这种新型组合剪力墙具有较强综合抗震耗能能力.
Keyword:
Reprint Author's Address:
Email:
Source :
地震工程与工程振动
ISSN: 1000-1301
Year: 2012
Issue: 4
Volume: 32
Page: 103-110
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count: 13
Chinese Cited Count:
30 Days PV: 14