Indexed by:
Abstract:
在大量试验的基础上构建了SBR法反硝化过程的模糊控制器,并进行了3种碳源投加方式的实时控制试验结果表明,按较小的速率连续投加碳源是最佳投加方式,它不仅可以满足反硝化速率上的要求,还可以尽量地减少再曝气时间.以pH和0RP作为SBR法反硝化时间和碳源投加的在线模糊控制参数是可行的和可靠的.
Keyword:
Reprint Author's Address:
Email:
Source :
环境科学学报
ISSN: 0253-2468
Year: 2003
Issue: 6
Volume: 23
Page: 733-737