Indexed by:
Abstract:
In recent years, concrete-filled steel tube (CFST) structures have been widely used in modern high-rise buildings. Compared with traditional circular and square CFST columns, elliptical concrete-filled steel tube (ECFST) columns show better structural performance such as higher torsion stiffness and flexural stiffness. The structural performance of ECFST columns at ambient temperature and in fire condition have been investigated by previous researchers. However, very limited research on the post-fire performance of ECFST columns has been conducted. In this paper, finite element analysis (FEA) models of ECFST stub columns were established to investigate their post-fire performance. In order to study the influence of section type on the post-fire performance of CFST stub columns, FEA models of circular and square CFST stub columns were also built to compare with the ECFST model. The temperature development in fire exposure stage, axial load versus average axial strain curves, load distribution and steel tube-core concrete interaction during the post-fire loading process were obtained and discussed.
Keyword:
Reprint Author's Address:
Email:
Source :
PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19)
Year: 2019
Page: 1459-1469
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 6
Affiliated Colleges: