In this experiment, the optical parameters of optical fiber sensing measurements with the wavelength division multiplexer (WDM) and Fiber Bragg grating have obtained in temperature-controlled cabinet. The wavelength division multiplexer device not only make different wavelength illuminant input at the same time be possible, but also can achieve multi-channel output based on the feature of WDM. We design and put forward a new method which can realize various parameters measured at the same time, such as temperature and the refractive index or stress measurement. In addition, it can measure the same parameters with different wavelengths of laser at the same time. The contrast analysis results of different wavelengths of illuminant on the same parameter sensitivity and reliability of the measurement will use to provide reference to design the same illuminant with different parameter measurements.