Indexed by:
Abstract:
The dynamic vibration absorber (DVA) is generally used to suppress the machining vibration in boring processes. The DVA consists of an additional mass-spring-damper sub-system, and needs accurately tuning of its natural frequency and damping ratio to match the main structure for vibration control. For obtaining the optimal performance of the DVA, the parameters of the DVA used in a boring bar is identified using modal correlation method, which combines the finite element analysis method with test modal method to validate the FEM's results. The analysis results show that the modal correlation method is an effective and simple method to accurately identify the dynamic parameters of DVA and guarantee the optimal design of the DVA for boring chatter control.
Keyword:
Reprint Author's Address:
Source :
MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4
ISSN: 1022-6680
Year: 2013
Volume: 753-755
Page: 1816-1820
Language: English
Cited Count:
WoS CC Cited Count: 1
SCOPUS Cited Count: 3
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: