Indexed by:
Abstract:
For obtaining fatigue limit and dealing with censored data, the" pair- life -weighted" is proposed in this paper. According to the fatigue testing of TA15 electron beam welded specimens, conventional methods and two methods in this article are used separately to calculate the fatigue limit and lognormal distribution parameters of the lives at different stress levels, and C-P-S-N curves are obtained and their corresponding mathematical expressions of 12 groups under 2 Confidence and 6 reliability are expressed as a three-parameter model. The results show that the" pair- life -weighted method "is in good agreement with the traditional method, when the lives have a difference of 3 times at the same stress, the fatigue limit only have a difference of 0.5%, it is the further evidence of the practicability in engineering about the traditional method.
Keyword:
Reprint Author's Address:
Source :
MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2
ISSN: 1660-9336
Year: 2013
Volume: 300-301
Page: 1222-,
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 5