Indexed by:
Abstract:
\Based on a pilot-scale an anaerobic/anoxic/oxic process, the study conducts chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) tests and analyzes mass balance for the A(2)/O system under different operational conditions(sludge retention time), and the results vividly reveal flow and distribution of the three pollution indexes in the whole system. And it will give real support to optimize the operating condition of an anaerobic/anoxic/oxic system.
Keyword:
Reprint Author's Address:
Email:
Source :
PROGRESS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL III: PROCEEDINGS OF THE 2011 INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY
Year: 2011
Page: 720-725
Language: English
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 10
Affiliated Colleges: