Indexed by:
Abstract:
Understanding of sealing performance of rural housing is very important in reducing energy consumption for heating demand. This paper illustrates the identification of infiltration rates through windows and doors in rural housing through temperature measurements. Room air temperatures were measured hourly from 2009-02-08 to 2009-02-17 in one rural housing in Beijing. During the measuring period, there is no one living in this house and all the windows and doors have been closed. The room air temperatures were simulated using DeST-h. The infiltration rate at each hour was identified by minimizing the gap between the measured temperature and the simulated temperature.
Keyword:
Reprint Author's Address:
Email:
Source :
2010 THE SECOND CHINA ENERGY SCIENTIST FORUM, VOL 1-3
Year: 2010
Page: 760-764
Language: Chinese
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 4
Affiliated Colleges: