The reinforced concrete column after corrosion of chloride salt was subjected to magnesium phosphate cement (MPC)-carbon fiber reinforced plastics (CFRP) reinforcement and electrochemical chloride extraction (ECE) integration experiment. The axial compression behavior of the reinforced concrete column was tested, and then the numerical analysis was carried out. Two types of the corroded reinforced concrete columns were prepared for the test. The columns in type 1 were naturally corroded, and the columns in type 2 were electrified to accelerate the corrosion until the theoretical mass corrosion rate of steel bars reached 15%. Afterward, the MPC-CFRP was used to strengthen the corroded reinforced concrete columns and to remove the inside chlorine by electrochemistry method. The test results showed that the ultimate compressive capacity of the reinforced concrete columns strengthened by the MPC-CFRP increased by more than 22.63%. However, after ECE (current density, 3 A/m(2)), the ultimate compressive capacity of the reinforced concrete columns strengthened by MPC-CFRP reduced by 3.07% - 3.66%, and the chloride ion content at the interface between steel bar and concrete reduced by 78.52%, which postponed the corrosion of the steel bars. In addition, considering the complex nonlinear bond slip relationship between the steel bar and the concrete interface, a 3D mesoscopic finite element plastic damage model of the reinforced concrete columns strengthened by the MPC-CFRP was established. The numerical results were in good agreement with the test results, which indicated the 3D mesoscopic finite element numerical model can predict the compressive behavior of the reinforced concrete columns adequately.

Keyword:

Reinforced concrete column Reinforcement Electrochemical chloride extraction Numerical simulation Axial compression behavior

Author Community:

  • [ 1 ] [Li, Yue]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing Key Lab Earthquake Engn & Struct Retrofit, Minist Educ, Beijing 100124, Peoples R China
  • [ 2 ] [Liu, Jianglin]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing Key Lab Earthquake Engn & Struct Retrofit, Minist Educ, Beijing 100124, Peoples R China
  • [ 3 ] [Wang, Zigeng]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing Key Lab Earthquake Engn & Struct Retrofit, Minist Educ, Beijing 100124, Peoples R China
  • [ 4 ] [Su, Yingqiu]Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Beijing Key Lab Earthquake Engn & Struct Retrofit, Minist Educ, Beijing 100124, Peoples R China
  • [ 5 ] [Li, Yue]Beijing Univ Technol, Coll Architecture & Civil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 6 ] [Liu, Jianglin]Beijing Univ Technol, Coll Architecture & Civil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 7 ] [Wang, Zigeng]Beijing Univ Technol, Coll Architecture & Civil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China
  • [ 8 ] [Su, Yingqiu]Beijing Univ Technol, Coll Architecture & Civil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China

Reprint Author's Address:

  • [Wang, Zigeng]Beijing Univ Technol, Coll Architecture & Civil Engn, 100 Pingleyuan, Beijing 100124, Peoples R China

Show more details

Related Keywords:

Source :

STRUCTURES

ISSN: 2352-0124

Year: 2021

Volume: 31

Page: 876-890

4 . 1 0 0

JCR@2022

JCR Journal Grade:2

Cited Count:

WoS CC Cited Count: 7

SCOPUS Cited Count: 8

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 7

Online/Total:780/10658156
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.