Free cooling technology can effectively reduce the cooling energy consumption of data centers, but its energy efficiency is greatly affected by regional and meteorological conditions. This study investigates the liquid-pumpdriven free cooling/mechanical refrigeration hybrid cooling system of a data center with 40 racks through a demonstration case and tests. The annual hourly energy efficiency in 20 subclimate zones and 37 typical cities in China of the hybrid cooling system designed with 5 and 10 degrees C temperature differences was analyzed with different meteorological parameters. The annual power usage effectiveness (PUE) values corresponding to the energy efficiency ratio (EER) in different regions were presented. Results showed that the annual average EER of the liquid-pump-driven free cooling mode was 7.07-14.18, and the annual average EER of the hybrid system was 4.22-14.10 when the temperature difference was 5 degrees C. The annual average EER range and the design temperature difference of the hybrid system for different climate regions were recommended. The PUE values of other regions, except for Guangzhou and Haikou, were lower than 1.40. The results provide references for the EER and PUE of the hybrid system in different climate regions.

Keyword:

Data center free cooling PUE Climate zone Liquid-pump-driven hybrid system EER

Author Community:

  • [ 1 ] [Zhou, Feng]Beijing Univ Technol, Fac Environm & Life, Dept Refrigerat & Cryogen Engn, Beijing 100124, Peoples R China
  • [ 2 ] [Shen, Chaoya]Beijing Univ Technol, Fac Environm & Life, Dept Refrigerat & Cryogen Engn, Beijing 100124, Peoples R China
  • [ 3 ] [Ma, Guoyuan]Beijing Univ Technol, Fac Environm & Life, Dept Refrigerat & Cryogen Engn, Beijing 100124, Peoples R China
  • [ 4 ] [Yan, Xianghui]Beijing Univ Technol, Fac Environm & Life, Dept Refrigerat & Cryogen Engn, Beijing 100124, Peoples R China
  • [ 5 ] [Zhou, Feng]Minist Educ China, Key Lab Enhanced Heat Transfer & Energy Conservat, Beijing, Peoples R China
  • [ 6 ] [Ma, Guoyuan]Minist Educ China, Key Lab Enhanced Heat Transfer & Energy Conservat, Beijing, Peoples R China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS

ISSN: 2213-1388

Year: 2022

Volume: 52

8 . 0

JCR@2022

8 . 0 0 0

JCR@2022

JCR Journal Grade:1

CAS Journal Grade:3

Cited Count:

WoS CC Cited Count: 15

SCOPUS Cited Count: 17

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:504/10583708
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.