• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Wei, Jianjian (Wei, Jianjian.) | Wang, Lei (Wang, Lei.) | Jin, Tao (Jin, Tao.) | Li, Yuguo (Li, Yuguo.) | Zhang, Nan (Zhang, Nan.) (Scholars:张楠)

Indexed by:

EI Scopus SCIE

Abstract:

To quantify the risk of the transmission of respiratory infections in indoor environments, we systematically assessed exposure to talking-and breathing-generated respiratory droplets in a generic indoor environment using computational fluid dynamic (CFD) simulations. The flow field in the indoor environment was obtained with SST k-omega model and Lagrangian method was used to predict droplet trajectories, where droplet evaporation was considered. Droplets can be categorized into small droplets (initial size <= 30 mu m or <= 10 mu m as droplet nuclei), medium droplets (30-80 mu m) and large droplets (>100 mu m) according to the exposure characteristics. Droplets up to 100 mu m, particular the small ones, can contribute to both short-range and long-range airborne routes. For the face-to-face talking scenario, the intake fraction and deposition fractions of droplets on the face and facial mucosa of the susceptible were up to 4.96%, 2.14%, and 0.12%, respectively, indicating inhalation is the dominant route. The exposure risk from a talking infector decreases monotonically with the interpersonal dis-tance, while that of nasal-breathing generated droplets maintains a relatively stable level within 1.0 m. Keeping an angle of 15 degrees or above with the expiratory flow is efficient to reduce intake fractions to <0.37% for small droplets. Adjusting the orientation from face-to-face to face-to-back can reduce exposure to small droplets by approximately 88.0% during talking and 66.2% during breathing. A higher ventilation rate can reduce the risk of exposure to small droplets but may increase the risk of transmission via medium droplets by enhancing their evaporation rate. This study would serve as a fundamental research for epidemiologist, healthcare workers and the public in the purpose of infection control.

Keyword:

Relative position Interpersonal distance Close contact Respiratory droplets COVID-19 Airborne route

Author Community:

  • [ 1 ] [Wei, Jianjian]Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Prov, Hangzhou, Peoples R China
  • [ 2 ] [Wang, Lei]Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Prov, Hangzhou, Peoples R China
  • [ 3 ] [Jin, Tao]Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Prov, Hangzhou, Peoples R China
  • [ 4 ] [Wei, Jianjian]Zhejiang Univ, Jiaxing Res Inst, Jiaxing, Peoples R China
  • [ 5 ] [Jin, Tao]Zhejiang Univ, Jiaxing Res Inst, Jiaxing, Peoples R China
  • [ 6 ] [Li, Yuguo]Univ Hong Kong, Dept Mech Engn, Hong Kong, Peoples R China
  • [ 7 ] [Zhang, Nan]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 8 ] [Zhang, Nan]Beijing Univ Technol, Beijing, Peoples R China

Reprint Author's Address:

  • [Zhang, Nan]Beijing Univ Technol, Beijing, Peoples R China;;

Show more details

Related Keywords:

Source :

BUILDING AND ENVIRONMENT

ISSN: 0360-1323

Year: 2023

Volume: 229

7 . 4 0 0

JCR@2022

ESI Discipline: ENGINEERING;

ESI HC Threshold:19

Cited Count:

WoS CC Cited Count: 32

SCOPUS Cited Count: 33

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 7

Affiliated Colleges:

Online/Total:664/10551246
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.