Indexed by:
Abstract:
Background and Objective: Screw loosening remains a prominent problem for osteoporotic patients undergoing pedicle screw fixation surgeries but its underlying mechanisms are not fully understood. This study sought to examine the interactive effect of craniocaudal or axial cyclic loading (toggling) and osteoporosis on screw fixation. Methods: QCT-based finite element models of normal (n = 7; vBMD = 156 ± 13 mg/cm3) and osteoporotic vertebrae (n = 7; vBMD = 72 ± 6 mg/cm3) were inserted with pedicle screws and loaded with or without craniocaudal toggling. Among them, a representative normal vertebra (age: 55; BMD: 140 mg/cm3) and an osteoporotic vertebra (age: 64; BMD: 79 mg/cm3) were also loaded with or without axial toggling. The individual and interactive effects of craniocaudal toggling and osteoporosis on screw fixation strength (the force when the pull-up displacement of the screw head reached 1 mm) and bone tissue failure (characterized by equivalent plastic strain) were examined by repeated measure ANOVA. Results: A significant interactive effect between craniocaudal toggling and osteoporosis on screw fixation strength was detected (p = 0.008). Specifically, craniocaudal toggling led to a marked decrease in the fixation strength (68%, p < 0.05) and stiffness (83%, p < 0.05) only in the osteoporotic vertebrae but had no effect on screw fixation strength and stiffness of the normal vertebrae (p > 0.05). Likewise, most of the bone tissues around the screw in the osteoporotic vertebrae yielded following craniocaudal toggling whereas this result was not seen in the normal vertebrae. The axial toggling had no significant effect on bone tissue failure as well as pedicle screw fixation in normal or osteoporotic vertebrae. Conclusions: Craniocaudal toggling substantially reduces the screw fixation strength of the osteoporotic vertebrae by progressively increasing tissue failure around the screw, and therefore may contribute to the higher rates of screw loosening in osteoporotic compared to normal patients, whereas axial toggling is not a risk factor for pedicle screw loosening in normal or osteoporotic patients. © 2023 Elsevier B.V.
Keyword:
Reprint Author's Address:
Email:
Source :
Computer Methods and Programs in Biomedicine
ISSN: 0169-2607
Year: 2023
Volume: 238
6 . 1 0 0
JCR@2022
ESI Discipline: COMPUTER SCIENCE;
ESI HC Threshold:19
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count: 6
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 7
Affiliated Colleges: