• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

刘毅超 (刘毅超.) | 樊洪明 (樊洪明.)

Abstract:

结合某实际工程,通过计算流体力学(CFD)软件scSTREAM对某洁净厂房进行数值模拟,运用计算流体力学的方法探讨了设备站脚高度对洁净厂房内的气流组织影响.结果表明:设备站脚为0.15m时有助于保障气流的单向流动性,减少涡流的产生.数值模拟的结果可以为洁净厂房的设计提供可行性的建议,从而针对性的提出优化设计方案.

Keyword:

设备站脚高度 电子洁净室 气流组织 计算流体力学

Author Community:

  • [ 1 ] [樊洪明]北京工业大学
  • [ 2 ] [刘毅超]北京工业大学

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Source :

洁净与空调技术

ISSN: 1005-3298

Year: 2023

Issue: 4

Page: 22-26