To study the effect of determination of damping matrix on the seismic response of nuclear power plant structures, fitting accuracy of the proportional damping of nuclear power plant structures and the influence of different shape of structures were considered. On this basis, a more precise model, that is, an equivalent proportional damping model was set up. Furthermore, a corresponding method for the seismic response analysis of nuclear power plant structures was proposed based on determining the proportional damping coefficient by weighted least square fitting method. The application and analysis show that the results by the proposed method are closer to the exact solutions than by the method with traditional damping coefficient, and it is suitable for the seismic response of nuclear power plant structures. ©, 2015, Chinese Vibration Engineering Society. All right reserved.