Indexed by:
Abstract:
Directing at the problem of torsional vibration occurred in the start-up procedures of long shaft drive transmission existed in printing equipment, we raised a variable structure control method based on Variable parameters fuzzy. The method not only displays feature of traditional non-linear variable structure control like nondeference derivation, planning the dynamic process and good capacity of resisting disturbance, but also able to effectively suppress the vibration generated when switching sliding mode surface. By means of simulation test and platform test, we prove that, compared with traditional PID controller, the PID controller with tracking differentiator in the staring process. The maximum overshoot of the system output is reduced to 4.8% from 72.2% and its adjustment time has been shortened 210ms, which help realize the improvement of start-up speed and vibration suppression. © 2014 ACADEMY PUBLISHER.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Networks
ISSN: 1796-2056
Year: 2014
Issue: 1
Volume: 9
Page: 78-84
ESI Discipline: COMPUTER SCIENCE;
ESI HC Threshold:188
Cited Count:
SCOPUS Cited Count: 1
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 9
Affiliated Colleges: