• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Wang, Wei (Wang, Wei.) | Di, Haoran (Di, Haoran.) | Tang, Rui (Tang, Rui.) | Wei, Wenzhe (Wei, Wenzhe.) | Sun, Yuying (Sun, Yuying.) | Dai, Chuanmin (Dai, Chuanmin.)

Indexed by:

EI Scopus SCIE

Abstract:

During the space heating in winter, the air source heat pump (ASHP) often encounters frosting problem. In former studies, it was found that the frosting performance of ASHP and indoor thermal environment vary significantly when the supply water temperature changes. However, the influence mechanism of supply water temperature is still unknown. To solve this problem, the frosting performance variations of ASHP and its effect on indoor thermal environment variations at the supply water temperature of 41-50 degrees C were investigated in the psychrometric chamber and artificial environmental chamber, respectively. Results showed that increasing supply water temperature can effectively suppress the frosting speed and reduce the impact of frosting-defrosting on indoor thermal environment. When the supply water temperature raises from 30 degrees C to 50 degrees C, the frosting duration prolongs from 50 min to 101 min. Meanwhile, the indoor temperature drop caused by frosting- defrosting decreased by about 45 % when supply water temperature rises from 41 degrees C to 50 degrees C. Besides, with the increase of supply water temperature, the impact of frosting on the heating performance of the ASHP decreases. When it rises from 30 degrees C to 50 degrees C, the attenuation degree of the average coefficient of performance during frosting-defrosting cycle drops from 9.85 % to 7.25 %, compared to those at non-frosting condition. However, although the frosting performance of ASHP and its effect on indoor thermal environment both get better with the increase of supply water temperature, the overall heating performance of the ASHP still declines.

Keyword:

Space heating Air source heat pump Frosting Indoor thermal environment Supply water temperature

Author Community:

  • [ 1 ] [Wang, Wei]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 2 ] [Di, Haoran]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 3 ] [Tang, Rui]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 4 ] [Wei, Wenzhe]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 5 ] [Sun, Yuying]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China
  • [ 6 ] [Wang, Wei]Beijing Polytech, Beijing, Peoples R China
  • [ 7 ] [Dai, Chuanmin]Qingdao Haier Smart Technol R&D Co Ltd, Qingdao, Peoples R China

Reprint Author's Address:

  • [Wei, Wenzhe]Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing, Peoples R China

Show more details

Related Keywords:

Source :

BUILDING AND ENVIRONMENT

ISSN: 0360-1323

Year: 2024

Volume: 267

7 . 4 0 0

JCR@2022

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 4

Affiliated Colleges:

Online/Total:848/11104136
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.