Abstract:
The steel-concrete composite slim floors, with the concrete slab laid on the lower flange of the steel section and the majority of steel beam encased in concrete slab, ensure the bonding force between steel and concrete and make them working well together. This paper presents an experimental study on a full-scale two-storey, two-bay by one-bay steel-concrete composite slim floor that was subjected to horizontal pseudo-dynamic loading. Based on the test results, the specimen shows high loading capacity and good ductility. The skeleton curves, structural deformation and the failure mode obtained from the pseudo-static loading tests are provided. Suggestions on the improvement of the composite beam-column connection is proposed.